CERN Accélérateur de science

CMS Detector Performance Summaries

Derniers ajouts:
2025-12-15
16:47
Performance of the parking Upsilon triggers in 2025 /CMS Collaboration
This note presents the performance of the triggers targeting $\Upsilon(\mathrm{nS}) \rightarrow \mu\mu$ decays that were part of the CMS High Level Trigger (HLT) menu during the 2025 data-taking period..
CMS-DP-2025-088; CERN-CMS-DP-2025-088.- Geneva : CERN, 2025 - 5 p. Fulltext: PDF;

Notice détaillée
2025-12-15
16:47
Profiling the CMS reconstruction options within the Calibration Loop /CMS Collaboration
This notes presents profiling results of the CMS Prompt Calibration Loop, aiming at delivering detector conditions within 48h of data taking to promptly reconstruct the CMS data using Tier0 resources. We present the performance of an alternative reconstruction configuration, with reduced tracking iterations, in order to deliver a subset of calibration constants within an 8h target and limited computing power..
CMS-DP-2025-087; CERN-CMS-DP-2025-087.- Geneva : CERN, 2025 - 9 p. Fulltext: PDF;

Notice détaillée
2025-12-15
16:47
Performances of a high rate single photon trigger in Run 3 /CMS Collaboration
This note presents the performances of a new trigger requiring the presence of an isolated photon with moderate transverse energy (ET $\approx$ 40-50 GeV) in the barrel region of the CMS detector ($\lvert\eta\rvert < 1.479$) deployed for the 2024 and 2025 data takings. The achieved threshold represents a reduction by more than a factor two with respect to previous data takings (110 GeV), opening the acceptance for a variety of analyses, including searches for Higgs decay into a photon and hadrons or missing transverse energy and searches relying on the presence of a photon radiation from the initial or final state. [...]
CMS-DP-2025-086; CERN-CMS-DP-2025-086.- Geneva : CERN, 2025 - 7 p. Fulltext: PDF;

Notice détaillée
2025-12-01
19:26
Enhancing CMS Passive Material Modeling in Track Reconstruction Using ACTS /CMS Collaboration
This exploratory study investigates whether the modelling of passive material in CMS track reconstruction can be improved through the use of an external software framework, A Common Tracking Software (ACTS)..
CMS-DP-2025-085; CERN-CMS-DP-2025-085.- Geneva : CERN, 2025 - 5 p. Fulltext: PDF;

Notice détaillée
2025-12-01
19:26
Performance of Level-1 Trigger e/$\gamma$ in 2025 proton-proton collisions at $\sqrt{s}$ = 13.6 TeV /CMS Collaboration
The performance of the Level-1 Trigger e/$\gamma$ objects during the 2025 proton-proton data taking is presented in this note..
CMS-DP-2025-084; CERN-CMS-DP-2025-084.- Geneva : CERN, 2025 - 14 p. Fulltext: PDF;

Notice détaillée
2025-12-01
19:26
Muon Tracking at the CMS High-Level Trigger for the HL-LHC Upgrade /CMS Collaboration
This note outlines the muon tracking performance at the CMS High-Level Trigger for the HL-LHC Upgrade. The Phase-2 muon system and the proposed HLT reconstruction strategies are described. [...]
CMS-DP-2025-083; CERN-CMS-DP-2025-083.- Geneva : CERN, 2025 - 41 p. Fulltext: PDF;

Notice détaillée
2025-12-01
19:26
Next Generation Triggers Demonstrator: Time Variation of the Calibrations and System Monitoring /CMS Collaboration
This note presents an overview of the Next Generation Triggers (NGT) Demonstrator in CMS. It summarizes studies of the effect of different calibrations on physics observables and their time-dependence. [...]
CMS-DP-2025-082; CERN-CMS-DP-2025-082.- Geneva : CERN, 2025 - 9 p. Fulltext: PDF;

Notice détaillée
2025-11-17
11:18
Flavour tagging performance of the updated Unified Particle Transformer algorithm with the CMS experiment at $\sqrt{s}$=13.6 TeV /CMS Collaboration
Recent advances in machine learning have delivered substantial gains across high-energy physics, particularly in object identification. In jet flavour classification, increasingly sophisticated architectures exploit low-level inputs and their correlations to improve performance. [...]
CMS-DP-2025-081; CERN-CMS-DP-2025-081.- Geneva : CERN, 2025 - 36 p. Fulltext: PDF;

Notice détaillée
2025-11-17
11:18
Jet Mass Reconstruction in the CMS Phase-2 Level-1 Trigger /CMS Collaboration
The Phase-2 upgrade of the CMS detector for the High Luminosity upgrade of the LHC (HL-LHC) includes the introduction of many new capabilities into the Level-1 trigger (L1T) subsystem. The latency will increase to $\sim$12.5 $\mu$s and the output bandwidth will increase to $\sim$750 kHz, while tracking and high-granularity calorimeter information will be available for the first time. [...]
CMS-DP-2025-080; CERN-CMS-DP-2025-080.- Geneva : CERN, 2025 - 18 p. Fulltext: PDF;

Notice détaillée
2025-11-17
11:18
Quality Control of the OBDT\_Theta board production for the Drift Tube Phase 2 Upgrade /CMS Collaboration
A dedicated test setup has been prepared at the CIEMAT laboratory in Madrid to perform the quality control of the new electronics boards produced for the Phase-2 Upgrade of the CMS Drift Tubes detector. A custom software framework was developed to select and efficiently execute a range of relevant tests, with the results analyzed and stored for future reference. This note presents a description of the setup and some of the results obtained from the first 137 OBDT\_Theta boards tested..
CMS-DP-2025-079; CERN-CMS-DP-2025-079.- Geneva : CERN, 2025 - 14 p. Fulltext: PDF;

Notice détaillée